Pagine elettroniche ; Ricerca
Semplificazione diagnostica della malattia
celiaca
SIMPLIFYING THE DIAGNOSIS OF COELIAC DISEASE; A recent experience with two different rapid tests
T. Not, S. Martelossi, S. Quaglia, F. Ferrara, A. Ventura
Clinica Pediatrica, IRCCS Burlo Garofolo, Università di Trieste
Giugno 2008 - pagg. 395 -397
Abstract
The Authors evaluated the sensitivity and specificity
of two commercial rapid tests for the diagnosis of coeliac
disease (CD). These assays were compared to a well-established
ELISA technique. Serum samples were analyzed from
114 biopsy-confirmed CD, 120 healthy controls, 20 first-degree
relatives of CD, and 75 diseased controls. The whole
blood samples were analyzed from 51 biopsy-confirmed coeliacs
and 100 controls. The serum-based test was positive in
all 114 coeliacs (sensitivity 100%). Among the controls there
were seven healthy blood donors, one first-degree relative,
and three affected controls who tested positive (specificity
94.9%). The rapid test was positive in 46 out of 51 (sensitivity
90.2%). All 100 controls tested negative (specificity 100%).
The commercial kits described produce high values of sensitivity
and specificity, offering the general practitioner a useful
tool to look for anti-h-tTG antibodies in his own medical office.
Parole chiave
Suggerite dall'AI
Classificazione MeSH
Corrispondenza: not@burlo.trieste.it